2X SYBR Green Fast qPCR Mix (No ROX) - HYA475
2X SYBR Green Fast qPCR Mix (No ROX) Cat. No. HYA475

Product Overview

2X SYBR Green Fast qPCR Mix (No ROX) is formulated for real-time quantitative PCR using SYBR Green I fluorescence detection. This 2X premix contains the essential qPCR components, including hot-start Taq DNA polymerase, Mg²⁺, dNTPs, and SYBR Green I. Only primers, DNA template, and nuclease-free water need to be added to prepare the reaction.

The antibody-mediated hot-start Taq DNA polymerase helps suppress nonspecific amplification during reaction setup, supporting improved amplification specificity. SYBR Green I enables fluorescence monitoring of double-stranded DNA accumulation throughout PCR, allowing target DNA quantification through Ct value analysis.

The ROX-free formulation is intended for real-time PCR instruments that do not require ROX reference dye. For instruments that require reference dye normalization, an appropriate ROX reference dye must be added separately according to the instrument manufacturer’s recommendations.

For routine qPCR workflows, amplicons of 70–200 bp are recommended. The mix is suitable for quantitative DNA analysis and can also be used with cDNA templates from two-step RT-qPCR. Store at -20°C protected from light, minimize repeated freeze-thaw cycles, and keep the reagent on ice during reaction preparation.

Product Features

  • Hot-Start Technology for Improved Specificity: Antibody-mediated hot-start Taq DNA polymerase helps reduce nonspecific amplification during reaction setup, supporting reliable real-time PCR analysis.
  • SYBR Green I-Based Real-Time Detection: SYBR Green I fluorescence enables monitoring of double-stranded DNA amplification and quantitative analysis based on Ct values.
  • Ready-to-Use 2X ROX-Free Formulation: Contains hot-start Taq DNA polymerase, Mg²⁺, dNTPs, and SYBR Green I in a convenient premix. The ROX-free formulation is suitable for compatible qPCR instruments that do not require reference dye.

FAQ

Q1: What is 2X SYBR Green Fast qPCR Mix (No ROX) used for?

It is designed for real-time quantitative PCR using SYBR Green I fluorescence detection to monitor DNA amplification and quantify target DNA. It can also be used for qPCR with cDNA generated by a separate reverse transcription reaction.

Q2: Can this mix be used on qPCR instruments that require ROX reference dye?

The mix does not contain ROX. For instruments that require ROX normalization, an appropriate reference dye must be added separately according to the instrument manufacturer’s instructions. Check your instrument’s requirements before use.

Q3: What amplicon length and reaction conditions are recommended?

Amplicons of 70–200 bp are recommended. A typical 20 µL reaction contains 10 µL of 2X mix, 0.4 µL each of 10 µM forward and reverse primers, template DNA, and nuclease-free water to volume. A common cycling program is 95°C for 3 minutes, followed by 40–45 cycles of 95°C for 5 seconds and 60°C for approximately 30 seconds, with fluorescence acquisition during the appropriate step. Optimize conditions for the target and instrument as needed.