One Step SYBR Green RT-qPCR Kit - HYA417
One Step SYBR Green RT-qPCR Kit Cat. No. HYA417

Product Overview

The HYA417 One Step SYBR Green RT-qPCR Kit is designed for real-time RNA analysis by combining reverse transcription and quantitative PCR in a single reaction tube. Using gene-specific primers and SYBR Green I fluorescence detection, the kit enables real-time monitoring of amplification without the need for post-PCR gel electrophoresis.

The optimized reaction system integrates reverse transcriptase and DNA polymerase in an enzyme mix to support efficient cDNA synthesis and subsequent amplification. This streamlined workflow is suitable for gene expression analysis and other RNA-based molecular biology applications, including experiments involving low-input RNA samples.

The kit requires gene-specific primers and is compatible with qPCR instruments according to their ROX reference dye requirements. Select the appropriate ROX dye, if needed, based on the instrument manufacturer’s recommendations. For optimal performance, amplicons of 70–200 bp are recommended. Store at -20°C and protect from light.

Product Features

  • One-Tube Reverse Transcription and qPCR: Combines cDNA synthesis and real-time PCR in a single tube, reducing hands-on steps and the risk of contamination from repeated tube handling.
  • SYBR Green I Real-Time Fluorescence Detection: Monitors double-stranded DNA amplification in real time, eliminating the need for post-amplification gel electrophoresis and supporting quantitative RNA analysis.
  • Integrated Enzyme Mix and Flexible ROX Compatibility: Combines the required enzymes in a convenient mix and supports use with qPCR instruments requiring no ROX, High ROX, or Low ROX, with the appropriate reference dye added separately when necessary.

FAQ

1. What applications is the One Step SYBR Green RT-qPCR Kit suitable for?

It is suitable for RNA quantification, gene expression analysis, and other applications requiring one-step reverse transcription and real-time PCR. The reaction combines cDNA synthesis and amplification in a single tube.

2. Does the kit include ROX reference dye?

ROX dye should be selected and added separately when required by the qPCR instrument. Check the instrument manufacturer’s instructions to determine whether no ROX, High ROX, or Low ROX is appropriate.

3. What are the recommended reaction conditions?

For a 20 µL reaction, use 10 µL of 2X reaction buffer, 0.8 µL of enzyme mix, 0.4 µL each of 10 µM forward and reverse primers, 2 µL of total RNA, the appropriate ROX dye if required, and nuclease-free water to the final volume. A typical program is reverse transcription at 42°C for 5 minutes, initial denaturation at 95°C for 1 minute, followed by 40 cycles of 95°C for 5 seconds and 60°C for 30–34 seconds. Amplicons of 70–200 bp are recommended. Optimize conditions for the target and instrument.