Product Overview
The HYA414 2X Blue Universal SYBR Green qPCR Mix with UDG is designed for real-time DNA quantification using SYBR Green fluorescence detection. The blue-colored premix helps visualize liquid handling during reaction setup, while the 2X formulation simplifies preparation by providing the core qPCR components in a single mix. Primers, DNA template, and nuclease-free water are added separately.
The mix incorporates hot-start Taq DNA polymerase to help improve amplification specificity and a dUTP/UDG system to reduce carryover contamination. UDG degrades uracil-containing DNA contaminants during the pre-reaction incubation, while the subsequent high-temperature step inactivates the enzyme before amplification.
A universal reference dye system supports compatibility with qPCR instruments requiring High ROX, Low ROX, or no ROX, helping simplify reagent selection across different platforms. The mix is suitable for applications such as gene expression analysis using cDNA templates and DNA quantification. Amplicons of 70–200 bp are recommended.
Store at -20°C, protected from light. For optimal performance, thaw and mix gently before use, avoid bubbles, and minimize repeated freeze-thaw cycles.
Product Features
- UDG-Based Carryover Contamination Prevention: The dUTP/UDG system helps degrade uracil-containing DNA contaminants before amplification, reducing the risk of carryover contamination in qPCR workflows.
- Blue Premix with Hot-Start Specificity: The blue color facilitates visual monitoring during reaction setup, while hot-start Taq DNA polymerase helps suppress nonspecific amplification.
- Universal Reference Dye Compatibility: The reference dye system supports qPCR instruments requiring High ROX, Low ROX, or no ROX, offering flexibility across different real-time PCR platforms.
FAQ
1. How does the UDG system help prevent qPCR contamination?
The dUTP/UDG system helps control carryover contamination by degrading uracil-containing DNA from previous amplification reactions during the UDG incubation step. A typical protocol includes 37°C for 2 minutes, followed by 95°C for 3 minutes before cycling. This system does not eliminate contamination from all sources.
2. Is this qPCR mix compatible with different real-time PCR instruments?
The universal reference dye system is designed for instruments requiring High ROX, Low ROX, or no ROX. Confirm compatibility with the specific instrument model and follow the instrument manufacturer’s recommendations.
3. What are the recommended reaction conditions?
For a 20 µL reaction, combine 10 µL of 2X mix, 2 µL of DNA template, 0.4 µL each of 10 µM forward and reverse primers, and nuclease-free water to the final volume. A typical program is 37°C for 2 minutes for UDG treatment, 95°C for 3 minutes, followed by 40 cycles of 95°C for 5 seconds and 60°C for 30–34 seconds. Amplicons of 70–200 bp are recommended. Optimize conditions according to the target and instrument.