Product Overview
The Double-Stranded RNA (dsRNA) ELISA Kit is an enzyme-linked immunosorbent assay (ELISA) designed for the quantitative measurement of double-stranded RNA (dsRNA) with a length above 40 base pairs, independent of sequence. This sequence-independent detection makes the kit broadly applicable across mRNA products regardless of their specific coding sequence, providing a standardized method for monitoring dsRNA byproduct levels — a key quality attribute for mRNA-based vaccines and therapeutics, where residual dsRNA can trigger unwanted innate immune activation. The assay employs a sandwich ELISA format coupled with a biotin-streptavidin amplification system. The microplate is pre-coated with anti-dsRNA capture antibody; dsRNA present in the sample binds to this antibody, after which a biotinylated anti-dsRNA detection antibody is added and binds to the captured dsRNA. Following washing, HRP-conjugated streptavidin is added and binds to the biotinylated detection antibody; unbound HRP-streptavidin is then washed away. TMB substrate is subsequently added and catalyzed by HRP to generate a blue color product, which turns yellow upon addition of an acidic stop solution. The resulting yellow color intensity is directly proportional to the amount of dsRNA captured on the plate, and is quantified by measuring absorbance at 450 nm. This kit supports mRNA quality control laboratories, mRNA vaccine and therapeutic developers, and CDMOs in accurately monitoring dsRNA levels throughout process development and release testing workflows.
Components
| Components | 48 T | 96 T |
| ELISA Microplate | 8×6 | 8×12 |
| Biotinylated detection antibody (100x) | 60 μL | 120 μL |
| HRP-streptavidin (100x) | 60 μL | 120 μL |
| Dilution buffer | 15 mL | 30 mL |
| TMB substrate solution | 6 mL | 12 mL |
| Stop solution | 3 mL | 6 mL |
| Concentrated wash buffer (20x) | 20 mL | 40 mL |
| Standard (UTP, 1ng/μL) | 7.5 μL | 15 μL |
| Standard (pUTP, 1ng/μL) | 7.5 μL | 15 μL |
| Standard (N1-Me-pUTP, 1ng/μL) | 7.5 μL | 15 μL |
| Standard (5-OMe-UTP, 1ng/μL) | 7.5 μL | 15 μL |
| STE buffer | 25 mL | 50 mL |
| Plate sealer | 2 pieces | 4 pieces |
Product Features
- detection limits: ≤0.001 pg/µL for UTP, pUTP and N1-Me-pUTP dsRNA; ≤0.01 pg/µL for 5-OMe-UTP dsRNA.
- Intra-assay and inter-assay CV ≤10%; reported recovery 80–120%.
- Four RNA-chemistry standards: UTP, pUTP, N1-Me-pUTP and 5-OMe-UTP dsRNA.
FAQ
Q1: Why is monitoring dsRNA levels important for mRNA-based products, and what does this kit measure?
Double-stranded RNA is a common byproduct of in vitro transcription reactions and can activate innate immune sensors (such as RIG-I, MDA5, and PKR) when present in mRNA products, potentially triggering unwanted immune responses and reducing therapeutic efficacy. This kit provides a quantitative, sequence-independent method for measuring dsRNA (above 40 bp) in mRNA samples, supporting process development and quality control efforts aimed at minimizing dsRNA contamination.
Q2: Can the assay be used for modified mRNA?
The kit includes UTP-, pUTP-, N1-Me-pUTP- and 5-OMe-UTP-dsRNA standards. Use the calibration series that is appropriate for the RNA chemistry being assessed.
Q3: What equipment is needed to run this assay, and how are results quantified?
The assay requires only a standard microplate reader capable of measuring absorbance at 450 nm, along with standard ELISA washing equipment (manual or automated plate washer). Results are quantified by comparing sample absorbance values to a standard curve generated using known dsRNA concentrations, allowing straightforward calculation of dsRNA content in unknown samples.