RNase Assay Kit (Fluorescence) - HYJ526
RNase Assay Kit (Fluorescence) Cat. No. HYJ526

Product Overview

The RNase Assay Kit (Fluorescence) provides a sensitive, real-time method for detecting RNase contamination based on a fluorophore-labeled RNA probe. In the absence of RNase activity, the probe remains structurally intact and stable, producing minimal fluorescence signal. When RNase activity is present in the sample, the probe is progressively degraded, releasing the fluorophore from its quenched state and resulting in a gradual increase in fluorescence signal over time. The rate of fluorescence increase is directly and positively correlated with the amount and activity of RNase present, enabling both qualitative detection and relative quantification of contamination levels. Signal is measured using a fluorescence microplate reader at an excitation/emission wavelength of 535/575 nm, allowing straightforward determination of whether a sample is contaminated with RNase activity. This assay format is well suited for quality control screening of enzyme preparations, reagent lots, and biological samples where RNase contamination could compromise the integrity of downstream RNA-based applications, including in vitro transcription reagents, mRNA production materials, and molecular biology kits.

Components

Components48 T192 T
10×reaction solution0.5mL2.0mL
RNA probe1tube1tube
TE buffer0.5mL2.0mL
RNase A standard (10mg/mL)10μL20μL
Standard Dilution Buffer6mL12mL
DNase&RNase-free water25mL25mL
DNase RNase away50mL50mL

Product Features

  • Real-time, kinetic fluorescence detection: The fluorophore-labeled probe enables continuous, real-time monitoring of RNase activity as fluorescence signal increases over the course of the reaction, allowing users to track degradation kinetics rather than relying solely on a single endpoint measurement.
  • Sensitive detection proportional to enzyme activity: The rate of fluorescence increase is directly correlated with both the amount and activity of RNase present in the sample, supporting sensitive detection of low-level contamination as well as relative quantification across samples.
  • Simple, standard-equipment workflow: Detection requires only a standard fluorescence microplate reader capable of measuring at 535/575 nm excitation/emission, making the assay accessible for routine QC screening without specialized instrumentation.

FAQ

Q1: How does this fluorescence-based assay detect RNase activity in a sample?

The assay uses an RNA probe labeled with a fluorophore that is quenched while the probe remains intact. When RNase activity is present in the tested sample, the enzyme degrades the RNA probe, separating the fluorophore from its quencher and releasing a fluorescence signal. As degradation continues, fluorescence intensity increases progressively, with the rate of increase reflecting the level of RNase activity present.

Q2: What types of samples or products is this kit typically used to screen for RNase contamination?

This kit is commonly used to screen for RNase contamination in enzyme preparations (such as recombinant proteins produced in bacterial or other expression systems), reagent lots used in RNA extraction, in vitro transcription, and mRNA production workflows, and other biological materials where residual RNase activity could degrade RNA-based products or compromise downstream RNA applications.

Q3: What equipment is required to run this assay, and how quickly can results be obtained?

The assay requires a fluorescence microplate reader capable of measuring at an excitation/emission wavelength of 535/575 nm. Because the assay is kinetic in nature, fluorescence signal can be monitored over a defined incubation period (following the protocol’s recommended reaction time) to assess RNase activity, with the presence or absence of a rising fluorescence signal directly indicating RNase contamination status.