RNase Inhibitor ELISA Kit - HYJ529
RNase Inhibitor ELISA Kit Cat. No. HYJ529

Product Overview

The RNase Inhibitor ELISA Kit employs an enzyme-linked immunosorbent assay (ELISA) coupled with a biotin-streptavidin amplification system for the quantitative detection of RNase inhibitor concentrations in samples — a relevant process residual to monitor when RNase inhibitor is used as a reaction additive in RT-PCR, RT-qPCR, or in vitro transcription workflows. The microplate used in this assay is pre-coated with anti-RNase inhibitor capture antibody. RNase inhibitor present in the sample binds to the immobilized antibody in the wells. A biotinylated anti-RNase inhibitor detection antibody is then added and binds to the captured RNase inhibitor. Following washing, HRP-conjugated streptavidin is introduced and binds to the biotinylated detection antibody; unbound HRP-streptavidin is subsequently removed by washing. TMB substrate solution is then added and catalyzed by HRP to generate a blue color product, which turns yellow upon addition of an acidic stop solution. The intensity of the yellow coloration is directly proportional to the concentration of RNase inhibitor in the sample, and is quantified by measuring absorbance (OD value) at 450 nm using a microplate reader. RNase inhibitor concentration is calculated by reference to a standard curve. This kit supports molecular biology and mRNA quality control laboratories, reagent manufacturers, and CDMOs in accurately monitoring RNase inhibitor levels throughout process development, raw material characterization, and release testing workflows.

Components

Components48T96T
ELISA Microplate8×68×12
Biotinylated detection antibody(100x)60uL120uL
HRP-streptavidin (100x)60uL120uL
Dilution buffer25mL50mL
TMB substrate solution6mL12mL
Stop solution3mL6mL
Concentrated wash buffer (10x)25mL50mL
Standard (0. 1mg/mL)25uL50uL
Plate sealer2 pieces4 pieces

Product Features

  • Sensitive detection via biotin-streptavidin amplification: The biotin-streptavidin-HRP detection cascade provides signal amplification, supporting sensitive and reliable quantification of RNase inhibitor, even at relatively low concentrations.
  • Specific antibody-based recognition: The pre-coated capture antibody combined with a biotinylated detection antibody provides specific binding to RNase inhibitor, minimizing cross-reactivity with other proteins present in the sample.
  • Standardized colorimetric readout for straightforward quantification: Results are read as a simple absorbance measurement at 450 nm using a standard microplate reader, providing a quantitative, reproducible readout suitable for routine residual protein monitoring in QC workflows.

FAQ

Q1: Why would RNase inhibitor concentration need to be monitored in a sample?

RNase inhibitor is commonly used as a reaction additive in RT-PCR, RT-qPCR, and in vitro transcription workflows to protect RNA from degradation. In applications where its residual presence or precise concentration is relevant to process development, raw material characterization, or quality control, accurate quantification helps ensure consistency and compliance with product specifications.

Q2: How does the biotin-streptavidin system enhance detection sensitivity in this assay?

The biotin-streptavidin interaction is one of the strongest known non-covalent biological interactions, enabling efficient binding of HRP-conjugated streptavidin to the biotinylated detection antibody. This creates a robust signal amplification step, improving the assay’s sensitivity for detecting lower concentrations of RNase inhibitor compared to a direct enzyme-labeled antibody format.

Q3: What equipment is required to run this assay, and how are results quantified?

The assay requires standard ELISA equipment, including a plate washer and a microplate reader capable of measuring absorbance at 450 nm. Results are quantified by comparing sample absorbance (OD) values to a standard curve generated using known concentrations of RNase inhibitor, allowing straightforward calculation of concentration in unknown samples.