Product Overview
HYB413 RT-LAMP Fluorescent Master Mix is a liquid reagent system designed for RNA detection by reverse transcription loop-mediated isothermal amplification (RT-LAMP). The system includes amplification buffer, an enzyme mix containing Bst DNA polymerase and a heat-resistant reverse transcriptase, fluorescent dye, and a lyophilization protectant.
With assay-specific primers and RNA template, HYB413 enables reverse transcription and strand-displacement amplification in a single isothermal reaction. The amplification buffer supplies essential reaction components, including magnesium ions and dNTPs, while fluorescence measurement allows amplification to be monitored in real time on compatible instruments.
The liquid format offers flexibility for reaction setup and assay optimization. The included lyophilization protectant also supports the development of freeze-dried reagent formats, with drying conditions and post-lyophilization performance established for the intended assay.
HYB413 provides a reagent platform for fluorescent RNA assay development, instrument-based molecular testing, and POCT reagent development.
Components
| Components | 96 T | 960 T | 9600 T |
| Loop-mediated Amplification Buffer | 1.2 mL | 4 mL×3 | 12 mL×10 |
| RT-Enzymes Mix | 245 μL | 2.45 mL | 2.45 mL×10 |
| Lyophilized protectant | 0.96 mL×2 | 9.6 mL×2 | 9.6 mL×20 |
| 25× Dye | 192 μL | 0.96 mL×2 | 0.96 mL×20 |
Product Features
- High Sensitivity and Strong Inhibitor Tolerance: HYB413 is optimized for sensitive RNA amplification even in challenging sample environments.
- High-Specificity Real-Time Fluorescent RT-LAMP: HYB413 combines reverse transcription, Bst-mediated strand displacement, and fluorescent detection in one reaction system.
- Liquid and Lyophilization-Ready Formulation: HYB413 can be used directly as a liquid RT-LAMP master mix or further developed into freeze-dried reagent formats.
FAQ
Q1: What is the main advantage of HYB413 compared with colorimetric RT-LAMP master mixes?
HYB413 uses fluorescence-based detection, allowing amplification to be monitored objectively by an instrument rather than relying on endpoint color interpretation.
Q2: Is HYB413 suitable for samples containing amplification inhibitors?
Yes. One of the key performance characteristics highlighted by Hyasen is strong inhibitor tolerance.
Q3: Can HYB413 be used to develop lyophilized RT-LAMP products?
Yes. HYB413 is specifically supplied as a liquid, lyophilization-ready master mix and includes a lyophilization protectant for freeze-dried formulation development.