RIG-1 dsRNA Detection Kit HYJ522

    Retinoic acid-inducible gene I (RIG-I) functions as a cytosolic pattern recognition receptor that initiates innate antiviral immunity by detecting exogenous viral RNAs. Structurally, RIG-I is comprised of three main functional domains –Caspase Activation and Recruitment Domain (CARD) for signal transduction, DExD/ H-box RNA helicase domain, and C-terminal domain for RNA binding. The RNA helicase domain is associated with RNA-dependent ATP hydrolysis activities, which is activated upon binding to double-stranded RNA (dsRNA), leading to the hydrolysis of ATP into ADP and inorganic phosphate (Pi). This kit quantifies dsRNA content in samples by measuring ADP production during the reaction between RIG-I and the sample. The assay is performed in a multi-well plate and can detect reactions in volumes as low as 5 μL.The detection involves three steps:

    1.RIG-I Reaction: Mix RIG-I enzyme, ATP, and the sample, followed by incubation.

    2.ATP Depletion: Add an equal volume of Reagent 1 to deplete residual ATP.

    3.ADP Detection: Add Reagent 2 to convert ADP back to ATP, which is then quantified using a luciferase/luciferin reaction. The luminescent signal is measured with a plate reader. dsRNA content is calculated based on a standard curve.

    Components

     

    Components

    96 T

    384 T

    RIG-I ATPase Reaction

    RIG-I enzyme(1µM)

    100µL

    400µL

    10× RIG-I Reaction Buffer

    0.25mL

    1mL

    1M DTT

    20μL

    50μL

    10mM ATP

    25μL

    100μL

    Standard (UTP, 25ng/μL)

    40μL

    150μL

    Standard (N1-Me-pUTP,25ng/μL)

    40μL

    150μL

    Measurement of ADP

    Reagent 1-Assay buffer

    0.5mL

    2mL

    Reagent 1-Enzyme(5×)

    0.125mL

    0.5mL

    Reagent 1-0.5M MnCl2

    25μL

    100μL

    Reagent 2

    1.25mL

    5mL

    384-well Plate

    1 plate

    1 plate

    Storage

    1.Dry Ice Shipping. Store the system at -25~- 15℃.

    2.Before use, all components should be thawed and mixed thoroughly at room temperature. Onceprepared, dispense all reagents into aliquots and store at -25~-15℃.Prepare the RIG-I system and Reagent 1 fresh for each use. Reagent 2 can be placed at room temperature (18–25°C) for 24 hours without significant signal loss.

    Additional Materials Required

    1.Chemiluminescence microplate reader.

    2.Microplate shaker.

    3.Handheld centrifuge.

    4.RNase-free tips and centrifuge tubes.