Leave Your Message

Sample Release Reagent ( LAMP Colorimetric ) HYB512

Hyasen has developed sample direct amplification lysis buffer specifically for molecular POCT diagnostic scenarios. This product is compatible with the LAMP Colorimetric.

Cat.No.: HYB512

Specification: 8 mL/100 mL/1000mL

    Hyasen has developed sample direct amplification lysis buffer specifically for molecular POCT diagnostic scenarios. This product is compatible with the LAMP Colorimetric. It does not require nucleic acid extraction and can be directly amplified with the sample crude lysate to accurately detect target genes, further shortening the sample detection time and matching the molecular POCT application requirements. It is suitable for sample types such as nasal swabs and throat swabs. The processed samples can be directly used for LAMP colorimetric detection without complex extraction operations, and the same results as conventional extraction methods can be achieved.

    Components

    Components

    Size-1

    Size-2

    Size-3

    Sample Release Reagent

     ( LAMP Colorimetric )

    8 mL

    100 mL

    1000 mL

    Storage

    This product should be transported and stored at room temperature.

    Instructions

    1. Take 800μl of Sample Release Reagent into a 1.5 mL sampling tube for later use;
    2. Use a swab to collect nasal or pharyngeal swabs;
    • Nasal swab: Take out a sterile swab and put it into the nostril, slowly push it to a depth of about 1.5 cm, gently rotate it 4 times along the nasal mucosa, and stay for more than 15 seconds, then use the same swab to repeat the same operation on the other nasal cavity.
    • Pharyngeal swab: Take out a sterile swab and gently and quickly wipe the bilateral pharyngeal tonsils and posterior pharyngeal wall 3 times.
    1. Place the swab immediately after collecting the sample in the sampling tube. The swab should be rotated and mixed in the preservation solution for at least 30 seconds to ensure that the sample is fully eluted in the sampling tube.
    2. Incubate at room temperature (20 ~ 25℃) for 1 min to complete the lysis preparation.
    3. Both 25μl system LAMP and RT-LAMP are compatible with 10μL template addition for detection experiments.

    Notes

    1. The minimum amount of Sample Release Reagent for a single swab can be adjusted to 400μl, which can be adjusted according to the test requirements.
    2. After the sample is processed with Sample Release Reagent, it is recommended to conduct the next test as soon as possible, and the interval time should not exceed 1h.

    Leave Your Message