RobuDirect Probe qPCR Premix plus-UNG - HYA425
RobuDirect Probe qPCR Premix plus-UNG Cat. No. HYA425

Product Overview

HYA425 RobuDirect Probe qPCR Premix plus-UNG is a specialized 2× master mix designed for direct probe-based real-time PCR detection without conventional nucleic acid extraction and purification.Its optimized enzyme and buffer system provides strong resistance to common PCR inhibitors, enabling direct DNA amplification from complex biological samples such as anticoagulated whole blood, plasma, serum, throat swabs, and saliva.The formulation contains a hot-start amplification enzyme, inhibition-resistant amplification components, UNG, optimized PCR Buffer, MgCl₂, dNTPs, stabilizers, and other essential reaction components. This ready-to-use design simplifies assay preparation while improving reaction consistency.A built-in UNG/dUTP carryover contamination-control system helps eliminate residual uracil-containing PCR products from previous amplification reactions, reducing the risk of false-positive results caused by amplicon and aerosol contamination.With its combination of direct amplification, strong inhibitor tolerance, probe-based detection, and contamination control, HYA425 is particularly suitable for demanding molecular diagnostic workflows, high-throughput testing, assay development, and complex sample analysis.

Components

2×RobuDirect Probe qPCR Premix plus-UNG

*This reagent contains hot start enzyme, UNG, PCR Buffer, MgCl2, dNTPs, stabilizer and other ingredients.

Product Features

  • Robust Direct qPCR from Complex Samples: HYA425 enables direct probe-based qPCR without conventional DNA extraction and purification in validated sample workflows.
  • Strong Inhibitor Tolerance for Reliable Amplification: The optimized formulation is designed to maintain amplification performance in samples containing common PCR inhibitors.
  • Integrated UNG/dUTP Carryover Contamination Control: HYA425 incorporates UNG together with a dUTP-containing reaction system to help prevent false-positive results caused by previous amplification products.

FAQ

Q1: Can HYA425 be used directly with biological samples without nucleic acid extraction?

Yes. HYA425 is specifically developed for direct probe-based qPCR amplification without conventional nucleic acid extraction and purification.

Q2: What is the main advantage of HYA425 compared with a conventional probe qPCR master mix?

The key advantage is its strong inhibitor tolerance combined with direct amplification capability.

Q3: How does the built-in UNG/dUTP system improve assay reliability?

The UNG/dUTP system is designed to reduce carryover contamination from previous PCR reactions.