Leave Your Message

RT-LAMP Fluorescent Master Mix (Lyophilized beads) HYB414

This product contains reaction buffer, RT-Enzymes Mix for Bst DNA polymerase and heat-resistant reverse transcriptase, lyophilization protector and fluorescent dye components. 

Cat.No.: HYB414

Specification: 96T/960T/9600T

    This product contains reaction buffer, RT-Enzymes Mix for Bst DNA polymerase and heat-resistant reverse transcriptase, lyophilization protector and fluorescent dye components. The reaction buffer contains Mg2+, dNTP and other components necessary for amplification. The product is lyophilized in pellet form, and only primers and templates need to be added for use.

    Components

    Components

    96 T

    960 T

    9600 T

    RT-LAMP Fluorenscent Master Mix(Lyophilized beads)

    8 T/strip×12

    8 T/strip×120

    8 T/strip×1200

    Storage

    Store at 2-8℃, valid for 12 months.

    Instructions

    1. Take out the corresponding number Lyophilized beads powder according to the number of tests.

    2. Prepare reaction mix

    Components

    Volume

    RT-LAMP Fluorenscent Master Mix

    (Lyophilized beads)

    1 piece(2 beads)

    10×Primer Mix*

    5 μ L

    Template DNA/RNA**

    45 μ L

    *10×Primer Mix Concentration: 16 μM FIP/BIP, 2 μM F3/B3,4 μM Loop F/B;

    **Nucleic acid templates are recommended to be dissolved using DEPC water.

    3. Reaction program

    Set the parameters on the PCR instrument (such as ABI7500) as follows:

    Temperature

    Time

    Cycles

    65℃

    60s

    *Collect fluorescent sign

    30

    Notes

    1. The reaction temperature can be optimized between 62°C and 68°C according to the primer conditions.

    2. The experiment shall be conducted in a standardized manner, including the preparation of reaction system, sample treatment and sample addition.

    3. It is suggested to prepare reaction system in the ultra-clean table and add templates in the fume hood of other rooms to avoid false.