Magnetic Plant DNA Kit - HYC253
Magnetic Plant DNA Kit Cat. No. HYC253

Product Overview

This kit provides a simple and efficient solution for plant DNA extraction. Following mechanical disruption of plant cells, DNA in the lysate binds to silica-coated magnetic beads under high-salt conditions. After washing, the DNA is eluted in Buffer EB or deionized water. DNA yield depends strongly on the sample type and the efficiency of cell disruption. The purified DNA is suitable for downstream applications, including next-generation sequencing (NGS) and PCR testing.

Components

Components96 T
Buffer PLS60 mL
Buffer ZB55 mL
Buffer GW1*80 mL
Buffer TB10 mL
RNase A (10 mg/mL)0.6 mL
Magnetic Microspheres N2×1 mL

Product Features

  • Silica-coated magnetic bead purification: Silica-coated magnetic beads bind DNA from plant lysates under high-salt conditions and release it in low-salt elution, giving a straightforward bind-wash-elute workflow that suits both manual and automated processing.
  • Flexible elution options: DNA can be eluted in Buffer TB or deionized water, so users can match the elution buffer to their downstream application.
  • Compatible with NGS and PCR detection: Purified DNA can be used directly in next-generation sequencing and PCR detection, supporting both routine analysis and sequencing-based plant genomics workflows.

FAQ

Q1: How can I improve DNA extraction from plants rich in polysaccharides and polyphenols?

Add β-mercaptoethanol to Buffer PLS to a final concentration of 5% to improve extraction performance.

Q2: What should I do if the extracted DNA performs poorly in downstream applications?

Poor performance in downstream applications is typically caused by one or more of the following:
Very low DNA concentration in the eluate: Refer to the troubleshooting recommendations in Section A6 above.
Residual magnetic beads in the eluate: Trace amounts of magnetic beads generally do not affect experimental results. If further removal is needed, place the tube containing the eluate on a magnetic rack, allow the beads to separate, and carefully transfer the supernatant to a new tube.
Residual salts: Add Buffer GW1 and 75% ethanol in the exact order specified in the protocol.
Excessive DNA input: Excess DNA may inhibit enzymatic reactions. Measure the DNA concentration using a spectrophotometer at 260 nm and carefully control the amount used.

Q3: How should Magnetic Microspheres N be stored and handled?

Do not freeze or centrifuge at high speed, as this may irreversibly damage the beads. Mix thoroughly before use to ensure a uniform suspension.