prou
Products
Taqman Multiplex qPCR Premix HCB5061B Featured Image
  • Taqman Multiplex qPCR Premix HCB5061B

Taqman Multiplex qPCR Premix


Cat No: HCB5061B

Package: 100RXN/1000RXN/10000RXN

Taqman Multiplex qPCR Premix master mix is a new generation antibody modified Taq DNA Polymerase fluroescence quantitative qPCR can be used in lyophilization reagent.

Product Description

Product detail

Cat No: HCB5061B

Taqman Multiplex qPCR Premix master mix is a new generation antibody modified Taq DNA Polymerase fluroescence quantitative qPCR can be used in lyophilization reagent. It is suitable for FAM/HEX/TET/ JOE/ROX etc. Double-labelled probes (also suitable for Molecular Beacon probes). The reagent contains hotstart Fast Taq DNA Polymerase, dNTP etc. Component which can be free-dried directly on the machine. The product does not contain ROX-corrected dyes and is suitable for various quantitative PCR models.


  • Previous:
  • Next:

  • Components

    Lyo-Ready TaqMan qPCR Mix

     

    Storage Conditions

    This product should be stored at -25~-15℃ away from light for 1 year.

     

    Instructions

    1.Reaction system 

    Components

    Volume (μL)

    Final concentration

    Enzyme Mix

    20

    -

    Primer Primer (10μM) 

    x

    0.1-0.5μM

    Probe Primer (10μM)

    x

    50-250nM

    DNA Tamplate

    1-25

    -

    dd H2O

    up to 25

    -

     

    2.Reaction program

    Cycle step

    Temp.

    Time

    Cycles

    Initial denaturation

    95℃

    5mins

    1

    Amplification reaction

    95℃

    15sec

    45

    Annealing/Extension

    60℃

    30sec

     Notes: In special cases the annealing/extension temperature can be adjusted according to the primer Tm value, 60°C is recommended.

     

    Lyophilization Process

    Procedure

    Temp.

    Set time

    Duration time  

    Pressure

    Pre-freezing

    -45℃

    10min

    60min

     

    Primary Drying

    -45℃

    10min

    60min

    0.01mbar

    -40℃

    10min

    600min

    0.01mbar

    -35℃

    10min

    120min

    0.01mbar

    -30℃

    20min

    60min

    0.01mbar

    -20℃

    20min

    60min

    0.01mbar

    -10℃

    20min

    60min

    0.01mbar

    0℃

    20min

    60min

    0.01mbar

     

    Secondary Drying

    5℃

    10min

    20min

    0.01mbar

    0.01mbar

    10℃

    10min

    20min

    15℃

    10min

    20min

    0.01mbar

    20℃

    10min

    20min

    0.01mbar

    25℃

    10min

    240min

    0.01mbar

     

     Notes

    1. This product is for research use only.

    2. Please operate with lab coats and disposable gloves, for your safety.

     
    Write your message here and send it to us